<LOGO>
FM Transmitter Measurement Report
Created: 2024-08-06 00-17-33
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 4/5, 58 dBuV SANDELS
Pilot RDS Phase Difference
6.7 kHz 5.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
20 kHz 55 kHz 3648 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,1 dBr 3,21 dBr 4,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 9 --:--
RT
-
AF EON
92.0, 94.7, 98.5, 106.3, 107.5 MHz -
FM Scope Max at: 55 kHz MIN: 20 kHz % above 76 kHz: 0,0000 Acquired: 2024/08/06 0.16.29 Total samples: 3648 Equivalent time: 0:03:02 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 50 100
FM Scope MAX: 4,1 dBr MIN: 2,1 dBr AVE: 3,21 dBr % above 12,2 dBr: 0,0 Last value: 2,6 dBr (2024/08/06 0.16.29) 00.02 00.04 00.06 00.08 00.10 00.12 00.14 00.16 0 2 4 Pm [dBr]